GENERAL| Memory | 1GB Data Flash Memory | | Operating Voltage | 10...30 V | | Protection (Device) | IP65 | | Protection (Sensor) | IP64 | | Backup Battery | 3.6V Lithium (for RTC) | | Monthly Time Deviation | ±1 min | | Logging Interval Options | 1', 5', 10', 15', ...60'...1440' | | Interface | RS-232, RS-485, USB | | Analog Output | 4–20 mA | | Display | 128x64 Graphic Dot Matrix LCD | | LCD Operating Temperature | -20°C to +70°C | | Keypad | 4 Button Keypad |
WIND SPEED| Sensor Type | Ultrasonic | | Measurement Range | 0…60 m/s | | Resolution | 0.01 m/s | | Accuracy | - ±0.2 m/s or ±2% (whichever is greater) for 0…35 m/s
- ±3% for >35 m/s
|
WIND DIRECTION| Sensor Type | Ultrasonic | | Measurement Range | 0…359.9° | | Resolution | 0.1° | | Accuracy | ±2° RMSE (from 1.0 m/s) |
| COMPASS| Sensor Type | Magnetic | | Measurement Range | 0…360° | | Resolution | 0.1° | | Accuracy | ±1° |
AIR TEMPERATURE (OPTIONAL)| Sensor Type | Pt100 | | Measurement Range | -40…+60°C | | Resolution | 0.1°C | | Accuracy | ±0.15°C ±0.1% |
RELATIVE HUMIDITY (OPTIONAL)| Sensor Type | Capacitive | | Measurement Range | 0…100% RH | | Resolution | 0.1% RH | | Accuracy | - @15–35°C: ±1.5% RH (0–90 RH), ±2% RH (above 90 RH)
- @-40 to +60°C: ±(1.5 + 1.5% of measurement) % RH
|
BAROMETRIC PRESSURE (OPTIONAL)| Sensor Type | Piezoresistive | | Measurement Range | 300…1100 hPa | | Resolution | 0.1 hPa | | Accuracy | ±0.5 hPa @ 20°C |
SOLAR RADIATION (OPTIONAL)| Sensor Type | Thermopile | | Measurement Range | 0…2000 W/m² | | Resolution | 1 W/m² | | Accuracy | Second Class Pyranometer |
|